Browse all practice questions for the ESCO Refrigeration Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Chill Champion: Conquer the 2026 ESCO Refrigeration Exam! course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Distinguish between refrigerant reclaim, recycling, and recap, and describe when each is required.
  • A thermal-electric (solid state) expansion valve is controlled by
  • Which of the following accurately describes EPA requirements for refrigerant recovery?
  • What is oil return and how do suction-side components help ensure it?
  • In the condenser example, the BTU transferred by the water is
  • Which component is primarily part of the high-side circuit in a typical refrigeration system?
  • Which statement is not true of a capillary tube metering device?
  • A centrifugal compressor is typically associated with which of the following characteristics?
  • A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms...
  • In the energy balance example, the heat gained by the water equals the heat lost by the refrigerant.
  • A decrease in superheat causes the TXV to begin to
  • What is the generally accepted range for evaporator air flow in cfms per ton of residential air conditioning?
  • Which vacuum level is typically targeted when evacuating a system to remove moisture?
  • A partially iced over evaporator can be caused by...
  • A residential split system had a compressor replaced last week; now the unit is not cooling properly. The evaporator seems starved of refrigerant. The liquid line is sweating where it leaves the dryer. This is most likely the result of:
  • In a pump-down system, where is the solenoid valve located?
  • What are safe practices for handling refrigerant cylinders, including weight checks and storage?
  • What is the function of a receiver in a refrigeration system, and when is a receiver used?
  • To remove as much moisture as possible from a system, what evacuation procedure is recommended?
  • Which option is NOT a TXV operating pressure?
  • Which practice helps ensure the correct oil type is used after service?
  • What is a microchannel coil and what are its advantages and maintenance considerations?
  • Which statement correctly describes high-side and low-side pressures and subcooling?
  • Which of the following best describes the typical relationship between evaporator outlet and inlet temperatures in a TXV system?
  • A mechanical shaft seal is necessary on a...
  • The oil pressure safety switch is operated by...
  • Why is purging lines with dry nitrogen during brazing important?
  • What is the purpose of the metering device in a vapor-compression refrigeration cycle?
  • A compressor that has a broken Reed valve will cause these symptoms...
  • Zero psia is:
  • A dirty evaporator in an air conditioning system will cause these symptoms...
  • When a TEV or a capillary tube is used as a metering device, a low refrigerant charge will cause...
  • How can you tell if the condensate drain is blocked and what steps fix it?
  • Which of the following is not a symptom of a hermetic system that is low on refrigerant?
  • Using a manifold gauge set, high-pressure readings primarily indicate which system area?
  • What pressure is sensed by the TXV's sensing bulb?
  • What is the typical state of refrigerant in the suction line?
  • Which statement best describes the condenser inlet state?
  • Which is not a thermodynamic property of refrigerants?
  • Before leak testing, what is a critical safety/environmental precaution you should take?
  • In a basic vapor-compression refrigeration cycle, which component is responsible for raising the pressure and temperature of the refrigerant vapor?
  • Solid contaminants such as sludge and carbon, from a severe hermetic compressor motor burnout are best removed...
  • Which safety attribute is a key reason for keeping refrigerant cylinders upright and away from heat?
  • Which statement best describes compressor types and their typical characteristics?
  • The clearance space in a reciprocating compressor
  • A low refrigerant charge in a system with an AXV metering device will result in which condition?
  • What is a typical result of an incorrect refrigerant charge?
  • The first function the condenser must perform is to ___ the refrigerant before condensing can occur.
  • A partially clogged capillary tube can cause which evaporator condition?
  • The evaporator's function is to:
  • Capillary tube metering devices are best described as
  • What steps should you take to verify system cleanliness after brazing or major repairs?
  • Which statement best contrasts electric defrost and hot-gas defrost in terms of heat source and typical use?
  • Which refrigerant is HCFC and commonly used in older residential HVAC systems?
  • In the evaporator, latent heat transfer occurs as the refrigerant boils and absorbs heat
  • Which component has no moving parts and is commonly used as a fixed restriction in metering?
  • What is the function of the evaporator in a vapor-compression refrigeration system?
  • An inefficient compressor is usually indicated by ___ head pressure and ___ suction pressure.
  • Frost on the suction line indicates:
  • An increase in head pressure causes ___ refrigerant to flow through a capillary tube.
  • In testing the efficiency of a water-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving water temperature?
  • What is the role of an accumulator in the oil return path?
  • The AXV best suited for operation under which condition?
  • What is the purpose of the receiver in a vapor-compression refrigeration system?
  • Which device is used to prevent evaporator pressure from falling below a set limit?
  • Which parameter does the oil pressure safety switch monitor?
  • Heat added to a vapor after the change of state is called?
  • Which OSHA electrical-safety standards apply to HVAC technicians working on energized equipment?
  • The temperature rise method of determining air volume can be used on:
  • Compared to R22 systems, the flow rate of a thermostatic expansion valve (TEV) in a 410A system is approximately what?
  • Which method can be used for leak detection with all high-pressure refrigerants?
  • Why is an inline filter-drier used and where is it placed in the system?
  • What is a typical purpose of a liquid-to-suction heat exchanger in refrigeration systems?
  • An accumulator is used to
  • Which type of expansion valve is described as solid-state and controlled by an NTC parameter?
  • Fan airflow pressures are usually measured in...
  • Which condition would you expect from an overcharged refrigerant in a capillary tube system?
  • Differentiating evaporator and condenser coils, where heat transfer occurs and what state changes take place?
  • A decrease in superheat causes the TXV to
  • A low pressure cut-off switch is used to...
  • Zero psig is the same as which condition?
  • Which statement correctly describes the evaporator pressure regulating valve (EPR)?
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature relative to the inlet is usually
  • The AXV is designed to maintain...
  • A TEV bulb which becomes detached from the suction line will cause these symptoms...
  • An inefficient compressor is usually indicated by which combination of head and suction pressures?
  • An overcharge of refrigerant will cause which condition?
  • Which indicators signal moisture in a refrigeration system and how can moisture compromise performance?
  • In a water-cooled condenser scenario, 10 lbs of refrigerant loses 20 BTU per lb, and 10 lbs of water passes through with the entering water at 80°F. What is the water leaving temperature?
  • The purpose of an evaporator pressure regulating valve (EPR) is to...
  • In an air conditioning system that uses a thermostatic expansion valve, the temperature of the evaporator outlet will usually be...
  • What is the function of a metering device in a refrigeration system?
  • When connecting copper to steel, the recommended brazing filler alloy is a...
  • Which condition is commonly associated with a low refrigerant charge in the system?
  • Which condition indicates the presence of frost on the suction line?
  • Which statement describes the function of an oil separator in a refrigeration system?
  • What is the purpose of a crankcase heater and when should it be energized?
  • What role does cylinder fill percentage play in refrigerant handling and what safety precautions should be followed?
  • What is a potential consequence of moisture in a refrigeration system?
  • Which condition is typically observed when a TEV bulb becomes detached from the suction line?
  • How should you prevent refrigerant oil from contaminating the suction line and what precautions apply when opening or brazing?
  • For an R410A system with a gauge reading of 124 psig and a suction line temperature of 54°F, what is the operating superheat?
  • A customer complains their air conditioning system runs constantly but does not cool well, the suction line is very cold and the compressor is sweating. The most likely cause is:
  • In a direct expansion evaporator system, the refrigerant entering the evaporator is best described as
  • Which statement about capillary tubes is true?
  • After observing a liquid line leak repair and system recharge, a noisy, hot compressor likely indicates which problem?
  • Where would a sight glass normally be located in a refrigerant system?
  • ___ can be used for leak detection with ALL high pressure refrigerants.
  • A decrease in superheat causes the TXV to begin to
  • Which methods remove moisture from a refrigeration system?
  • Water enters a condenser at 80°F and leaves at 100°F; what is the water temperature rise?
  • Which of the following statements best describes the evaporator airflow requirement for residential AC?
  • After installing a new system, describe a standard charging procedure using the superheat method and what data to record.
  • What is refrigerant recovery efficiency and why is it important for compliance?
  • Electric defrost and hot-gas defrost cycles operate and what are practical differences?
  • Between which components is the liquid line filter dryer installed?
  • Which statement about slight suction-line superheat is true?
  • Where should the liquid line filter dryer be installed in a typical DX system?
  • What is the function of the condenser in a vapor-compression refrigeration system?
  • What is the typical target superheat for common residential systems?
  • What is the state of refrigerant entering the condenser?
  • Three basic types of condensers are water cooled, air cooled, and ___ cooled.
  • What is the purpose of a liquid-line filter-drier and where should it be installed?
  • How can you tell if a system uses R-410A versus R-22 from labeling and service data, and why does it matter for pressures?
  • Which of the following is a typical sign of a malfunctioning TXV/EEV?
  • The temperature at which moisture will start to condense from the air is called
  • What maintenance consideration is particularly important for microchannel coils?
  • A TXV is designed to maintain...
  • Which electrical checks help prevent compressor overload?
  • What is the purpose of a micron gauge in vacuum testing of refrigeration systems?
  • During condensation, the refrigerant releases heat to the surroundings.
  • When mounting a TXV sensor bulb, which of the following is NOT true
  • Which of the following cannot be used as a low ambient temperature control?
  • List common reasons for a system to display low refrigerant charge and how to verify each.
  • A system with a leak in the liquid line was repaired, evacuated, and recharged. When started, the compressor is noisy and running hot. The most probable cause is...
  • Compare R-407C and R-404A in terms of typical applications and operating temperatures.
  • In a vacuum of 28 inches of mercury, at what temperature will water begin to vaporize?
  • When an AXV is used as a metering device, a low refrigerant charge will cause...
  • At a residential service call with no cooling and unit completely out of refrigerant, the technician decides to use a trace amount of refrigerant and ___ in order to pressurize the system
  • Capillary tube metering devices are described as which type of restriction?
  • A refrigerant gives up heat when:
  • In which applications is R-404A typically used?
  • Which action best removes solid contaminants after a severe hermetic compressor burnout?
  • Which gauge is used to measure vacuum at the micron level in HVAC systems?
  • In a DX evaporator system, the refrigerant enters the evaporator as
  • If the line temperature is 70°F and the pressure corresponds to a saturated suction temperature of 42°F, what is the system's superheat?
  • What does the sensing bulb of a TXV/EVV do and where should it be placed?
  • A restriction in the metering device can cause which evaporator condition?
  • Which fault is most likely to cause high suction pressure and high discharge pressure in an air conditioning system?
  • Refrigerant R-134a vapor enters the condenser at 124 psig, 100°F and leaves at 80°F. Its pressure will be approximately...
  • Air or other noncondensable gases in a capillary tube air conditioning system will cause these symptoms.
  • A TXV has three operating pressures...
  • An air conditioning system that is oversized can cause...
  • The main function of the condenser is
  • Which term describes heat transfer during vaporization?
  • A liquid to suction heat exchanger is often used to...
  • The temperature rise method of determining air volume is applicable to which equipment?
  • Which loads should the evaporator coil design primarily address?
  • How does UV dye leak detection work and what color indicates a leak under UV light?
  • Which of the following is a common cause of compressor short cycling and how would you diagnose it?
  • The heat removed from the refrigerant by the condenser is which type of heat?
  • What is the maximum operating pressure setting for an acetylene torch?
  • Which statement best describes the regulatory guidance for reclaim, recycling, and recap of refrigerants?
  • What are common methods for leak testing refrigerant circuits and what precautions should you take?
  • How is superheat adjusted on many metering devices?
  • Why should nitrogen be used to pressurize or purge a system prior to leak testing and brazing?
  • Which oils are commonly used in refrigerant systems, and what steps help prevent cross-contamination when replacing oil?
  • The main function of the condenser in a refrigeration system is to remove heat from the refrigerant.
  • A low refrigerant charge in an air conditioning system will cause these symptoms...
  • Bubbles in the sight glass could indicate which condition in a system using a thermostatic expansion valve?
  • A OF a TEV bulb that has detached from the suction line will typically produce which pressure condition?
  • Which statement is not true about a capillary tube metering device?
  • A liquid receiver is used to
  • What is the primary purpose of a service valve in a refrigeration system?
  • In an R134a system, the high pressure gauge reads 143 psig and the liquid line temperature at the condensing unit is 95°F. What is the operating system superheat?
  • Why is proper documentation of service data and test results important in refrigeration work?
  • When using an electronic leak detector, at what rate should the sensor probe be moved to survey for leaks?
  • How is superheat defined?
  • When diagnosing a compressor that won't start, which step best aligns with a proper starting-issue checklist?
  • What is the minimum vertical drop from the outlet of the condensate drain pan to the inlet of the P trap?
  • A compound pressure gauge measures
  • Which statement best describes the reason for slight suction-line superheat in a refrigeration system?
  • Before opening a vapor compression system for service, what must be done with the refrigerant?
  • Subcooling is defined as which of the following?
  • Why is adequate airflow across the evaporator essential, and what are common causes of restricted airflow?
  • How is subcooling measured, and what does it indicate about system performance?
  • If excess refrigerant is charged into a system, the result is typically
  • What type of gauge is used to measure microns?
  • Which maintenance step helps prevent compressor overload in hot weather conditions?
  • What is the primary purpose of an accumulator?
  • A low refrigerant charge in a system using both TEV and capillary tube will cause which pressure change?
  • What is the function of a low-pressure switch in a compressor-controlled system and what fault conditions could trigger it?
  • Provide approximate normal high-side and low-side pressure ranges for R-410A at typical outdoor temperatures.
  • In the evaporator, the refrigerant absorbs latent heat from the space which causes it to
  • How does humidity affect evaporator frosting and energy efficiency?
  • Which sequence correctly describes how to calculate evaporator outlet superheat?
  • When topping off an operating system containing a blended refrigerant, how should the refrigerant be introduced?
  • While troubleshooting a residential split system, the service technician finds low operating pressures and low system amperage draw. This could be an indication of:
  • Before servicing a system, what equipment is required to handle refrigerant safely?
  • Liquid line sweating near the dryer is most likely caused by:
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature is usually
  • When charging a system, how do you decide whether to use the superheat method or the subcooling method?
  • A faulty condenser fan motor on an air conditioning system will cause these symptoms...
  • The heat removed from the refrigerant by the condenser is
  • Why is a vacuum applied to the isolated section before re-pressurizing after service?
  • Which symptom would indicate an oil-logged condenser?
  • Which factor does a TXV primarily respond to in regulating refrigerant flow?
  • In testing the efficiency of an air-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving air temperature?
  • Removing the cut off plate from a blower assembly would most directly affect which parameter?
  • Why is refrigerant-oil compatibility important and what steps should you take when replacing oil?
  • Which of the following describes proper PPE and lockout/tagout practices when servicing refrigeration equipment?
  • If the cut off plate is removed from a blower assembly, how would this effect blower performance?
  • Which statement is not true about capillary tube metering devices?
  • Why is unobstructed condenser airflow crucial?
  • A rise in evaporator pressure causes the AXV to begin to
  • What is the recommended evacuation procedure to remove moisture from a system?
  • An overcharge of refrigerant will cause:
  • Which statement best describes a thermostatic expansion valve and a capillary tube in terms of control, efficiency, and operating range?
  • Back seating a two-way service valve results in which condition?
  • Which of the following types of air conditioning compressors is most energy efficient?
  • Why is nitrogen or dry purge used during brazing of refrigerant piping?
  • Which statement about capillary tubes is true?
  • In the evaporator, latent heat is transferred from the refrigerated space to the refrigerant.
  • Which statement defines the dew point temperature?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy